Using Resistivity Measurements for Dam Safety Evaluation at Enemossen Tailings DamNormal access

Authors: P. Sjödahl, T. Dahlin and S. Johansson
Event name: Near Surface 2004 - 10th EAGE European Meeting of Environmental and Engineering Geophysics
Session: Geophysical Application in Civil Engineering 2
Publication date: 06 September 2004
Organisations: EAGE
Language: English
Info: Extended abstract, PDF ( 383.03Kb )
Price: € 20

Summary:
A017 USING RESISTIVITY MEASUREMENTS FOR DAM SAFETY EVALUATION AT ENEMOSSEN TAILINGS DAM 1 SJÖDAHL P.* DAHLIN T.* JOHANSSON S.** * Dept. of Engineering Geology Lund University Box 118 221 00 Lund Sweden pontus.sjodahl@tg.lth.se torleif.dahlin@tg.lth.se ** HydroResearch Sam Johansson AB St. Askens väg 6 183 65 Täby Sweden sam.johansson@hydroresearch.se INTRODUCTION Internal erosion is one of the major reasons for embankment dam failures. Resistivity measurements may have the possibility of detecting internal erosion processes and anomalous seepage at an early stage before the safety of the dam is at stake. The technique is essentially non-destructive which is particularly important when working with