An electrochemical hydrophone based on the principles of molecular electronic transfer (MET) was described. The work presents experimental results for the sensitivity, frequency response and intrinsic noise level. It has been demonstrated the experimental device has 0.8 mV/Pa sensitivity in the frequency band 0.02–200 Hz and low frequency self-noise close to Wenz model. Easy to fabricate, cheap and suitable for mass production the MET Hydrophone could be in demand in marine and tranzient zone seismic survey.

Loading

Article metrics loading...

/content/papers/10.3997/2214-4609.201801629
2018-06-11
2024-04-26
Loading full text...

Full text loading...

References

  1. Abramovich, I.A. and Kharlamov, A.V.
    [2003] Electrochemical transducers and a method for fabricating the same. U.S. Patent 6576103B2.
    [Google Scholar]
  2. Agafonov, V. M., Egorov, I. V. and Shabalina, A. S.
    [2013] Operating principles and specifications of small-size molecular electronic seismic sensor with negative feedback. Seismic Instrum., vol. 49, no. 1, pp. 5–19
    [Google Scholar]
  3. Antonovskaya, G. N., Kapustian, N. K., Moshkunov, A. I., Danilov, A. V. and MoshkunovK. A.
    [2017] New seismic array solution for earthquake observations and hydropower plant health monitoring. J Seismol, 21: 1039. https://doi.org/10.1007/s10950-017-9650-8
    [Google Scholar]
  4. Deng, T., Chen, D., Chen, J., Sun, Z. and Wang, J.
    [2016] Microelectromechanical Systems-Based Electrochemical Seismic Sensors With Insulating Spacers Integrated Electrodes for Planetary Exploration. IEEE SENSORS JOURNAL, VOL. 16, NO. 3, FEBRUARY 1, 2016.
    [Google Scholar]
  5. Egorov, I. V., Shabalina, A. S. and Agafonov, V. M.
    [2017] Design and Self-Noise of MET Closed-Loop Seismic Accelerometers. IEEE SENSORS JOURNAL, VOL. 17, NO. 7, APRIL 1, 2017.
    [Google Scholar]
  6. Holcomb, L. G.
    [1989] A Direct Method for Calculating Instrument Noise Levels in Side-by-Side Seismometer Evaluations. USGS Open-FUe Rep.89–214.
    [Google Scholar]
  7. Huang, H., Liang, M., Tang, R., Oiler, J. and Yu., H.
    [2013] Molecular Electronic Transducer-Based Low-Frequency Accelerometer Fabricated With Post-CMOS Compatible Process Using Droplet as Sensing Body. IEEE ELECTRON DEVICE LETTERS, VOL. 34, NO. 10, OCTOBER 2013, p. 1304–1306
    [Google Scholar]
  8. Levchenko, D.G., Kuzin, I.P., Safonov, M.V., Sychikov, V.N., Ulomov, I.V., and Kholopov, B.V.
    [2010] Experience in seismic signal recording using broadband electrochemical seismic sensors, Seism. Instruments, vol. 46, no. 3, pp. 250–264.
    [Google Scholar]
  9. Zaitsev, D.L., Agafonov, V.M., Egorov, E.V., Antonov, A.N. and Krishtop, V.G.
    [2016] Precession azimuth sensing with low-noise molecular electronics angular sensors. J. Sensors, vol. 2016, Art. no. 6148019.
    [Google Scholar]
http://instance.metastore.ingenta.com/content/papers/10.3997/2214-4609.201801629
Loading
/content/papers/10.3997/2214-4609.201801629
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error